Certificatore per impianti in Fibra Ottica Multimodali e Monomodali.
Codice Fluke | Descrizione |
CertiFiber Pro Models |
I modelli CertiFiber Pro sono disponibili in 2 versioni: wireless e non-wireless. |
CFP2-100-S | 1 Versiv Mainframe & Remote, (2) CertiFiber Pro Singlemode OLTS modules, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB interface cable, LinkWare Software CD, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo |
CFP2-100-M |
1 Versiv Mainframe & Remote, (2) CertiFiber Pro Multimode OLTS Modules, SC/LC EF-compliant MM TRC Kit 50 um, TRC Carrying Case, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo |
CFP2-100-Q | 1 Versiv Mainframe & Remote, (2) CertiFiber Pro Quad OLTS modules, SC/LC EF-compliant MM TRC Kit 50 µm, SC/LC SM TRC Kit, TRC Carrying Case, (2) LC/LC Simplex Adaptors, (2) HandStraps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo |
CFP2-100-QI |
CertiFiber Pro Quad OLTS with double ended inspection. This kit includes (2) Versiv Mainframes, (2) CertiFiber Pro Quad OLTS Modules, (2) USB fiber inspection video probes each with 4 tips, Multimode Encircled Flux compliant test reference cord kit (2m) for testing 50um LC terminated fibers (2 SC/LC, 2 LC/LC), Singlemode test reference cord kit (2m) for testing 9um LC terminated fibers (2 SC/LC, 2 LC/LC), TRC Carrying Case, (2) 1.25 mm Quick Clean Cleaners, (2) 2.5 mm Quick Clean Cleaners, (2) LC/LC Adaptors, (2) Hand Straps, (2) Shoulder Straps, Carry Case, USB Interface Cable, Versiv Open Source Software CD, (2) AC Chargers, Integrated Wi-Fi, Statement of Calibration and Getting Started Guide. See Photo |
Power Meter Specifications | |
Input Connector | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |
Detector Type | InGaAs |
Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |
Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |
Power Measurement Uncertainty1,2 | < +/- 5% +/- 32 pW |
Measurement Linearity3 | < ± 0.1 dB |
Re-calibration Period | 1 year |
Integrated Wi-Fi | Meets IEEE 802.11 a/b/g/n; dual band (2.4 GHz and 5 GHz) |
Loss/Length Specifications | ||
Specification | CertiFiber Pro Multimode Modules | CertiFiber Pro Singlemode Modules |
Testing Speeds (excludes referencing times) | Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) |
|
Input/Output Connectors | Interchangeable connector adapter (LC standard, SC, ST and FC optional) | |
Launch Condition1,2 | Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 | |
Fiber Types Tested | 50/125 µm or 62.5/125 µm | singlemode |
Source Type and Wavelengths | LED source 850 nm ± 30 nm 1300 nm ± 20 nm | Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm |
Maximum Length Measurement | 12 km | 130 km |
Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length | ± 1.5 m plus ± 1 % of length |
Output Power (Nominal) | ≥ -24 dBm with EF-TRC | ≥ -4 dBm |
Output Power Stability3 | ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes | ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes |